Bouwbesluit Online 2012


NEN-EN 1993-4-1:2007+A1:2017+NB:2012 en

Eurocode 3: Ontwerp en berekening van staalconstructies

Deel 4-1: Silo's

Publicatiedatum: 01 maart 2007

Publicatiedatum A1: 01-07-2017

Inclusief NEN-EN 1993-4-1:2007/C1:2009 en

Inclusief NEN-EN 1993-4-1:2007/A1:2017 en

Inclusief NEN-EN 1993-4-1:2007/NB:2012 en

Vervangt NVN-ENV 1993-4-1:1999 en

Let op: De tekst van de Nationale Bijlage is in herkenbaar oranje geïntegreerd in de tekst van de Eurocode.

Samenvatting
Part 4.1 of Eurocode 3 provides principles and application rules for the structural design of steel silos of circular or rectangular plan-form, being free standing or supported. The provisions given in this Part supplement modify or supersede the equivalent provisions given in EN 1993-1. This part is concerned only with the requirements for resistance and stability of steel silos. For other requirements (such as operational safety, functional performance, fabrication and erection, quality control, details like man-holes, flanges, filling devices, outlet gates and feeders etc.), see the relevant standards. Provisions relating to special requirements of seismic design are provided in EN 1998-4, which complements or adapts the provisions of Eurocode 3 specifically for this purpose. The design of supporting structures for the silo are dealt with in EN 1993-1-1. The supporting structure is deemed to consist of all structural elements beneath the bottom flange of the lowest ring of the silo, see figure 1.1. Foundations in reinforced concrete for steel silos are dealt with in EN 1992 and EN 1997. Numerical values of the specific actions on steel silos to be taken into account in the design are given in EN 1991-4 Actions in Silos and Tanks. This Part 4.1 does not cover: resistance to fire; silos with internal subdivisions and internal structures; silos with capacity less than 10 tonnes; cases where special measures are necessary to limit the consequences of accidents. Where this standard applies to circular planform silos, the geometric form is restricted to axisymmetric structures, but the actions on them may be unsymmetrical, and their supports may induce forces in the silo that are not axisymmetrical.

Uw gekozen filters:

Type

Gebruiksfuncties

Beeld: John van Helvert

Bouwbesluit online is niet meer beschikbaar. De actuele regels zijn te vinden in het Besluit Bouwwerken Leefomgeving (BBL) op:

BBLonline
bblonline.nl
wettenbank.overheid.nl
De Rijksoverheid. Voor Nederland